Which data center cooling business models will capture AI demand?

Whether you're building or investing in the data center cooling market, our report covers everything you need to know: the players, the money, and what's coming next.
Summary
Integrated chip-to-chiller cooling platforms are positioned to capture the most AI demand, with CDUs, large chillers, retrofit engineering and lifecycle services taking the strongest individual slices of spending underneath them.
The biggest cooling opportunity is broader than liquid cooling inside the rack. AI is increasing spending all the way from cold plates and manifolds to pumps, CDUs, chillers, heat rejection, controls and commissioning, so suppliers covering several layers can collect more revenue from the same megawatt.
Direct-to-chip liquid cooling looks like the mainstream winner for dense AI racks. Immersion can handle extreme heat loads, but it asks operators to change much more of the server and maintenance model, which makes it harder to deploy at scale.
CDUs have unusually clean exposure to the AI build-out because their required capacity rises with the amount of heat moved into liquid. The downside is that the category is becoming crowded quickly, so qualification, manufacturing scale and integration will matter more as hardware standardizes.
Chillers may capture more absolute AI cooling dollars than the rack-level technologies receiving most of the attention. Multi-hundred-megawatt campuses ultimately have to reject enormous amounts of heat, and recent capacity agreements and factory expansions suggest this equipment is already becoming a bottleneck.
Hybrid air-and-liquid cooling is likely to be a much bigger market than an all-liquid thesis suggests. GPU racks may require liquid, while networking, storage, older servers and less dense compute can remain air cooled inside the same facility.
Retrofit work is particularly attractive because most of the installed data center estate was not built for today's rack densities. Putting high-density liquid cooling into an awkward existing site requires engineering, controls, commissioning and operational knowledge that is harder to commoditize than a standard piece of hardware.
Lifecycle services could become the best recurring-revenue layer. Every new liquid-cooled megawatt creates pumps, filters, coolant chemistry, valves and fluid loops that need to be tested, maintained and managed for years after the initial equipment sale.
Water constraints are starting to affect architecture choices rather than just sustainability reporting. If access to water can delay or block a large AI campus, zero-water or low-water cooling designs gain economic value well beyond the price of the cooling equipment itself.
Manufacturing capacity is becoming part of the product. Modine's multi-billion-dollar capacity agreement and expansion by suppliers such as Vertiv show that AI developers increasingly care about guaranteed delivery, qualification and global service alongside thermal performance.
The strongest economics therefore sit with suppliers that can combine technology, manufacturing and installed-base revenue. A clever component can grow very quickly during the liquid-cooling transition, but controlling more of the thermal path from GPU to outside air creates the more durable business.
Written by the New Market Pitch teamWe track new markets so founders and investors can move faster. About us

When the price drops below the right threshold, everything speeds up. We track it closely in our data center cooling market report.
Why is AI changing the data center cooling business so much?
AI has turned data center cooling from a supporting infrastructure category into one of the things that can determine whether a new GPU cluster can be deployed at all.
NVIDIA's GB200 NVL72 puts 72 Blackwell GPUs and 36 Grace CPUs into a liquid-cooled rack-scale system. GB300 NVL72 follows the same basic direction. At the facility level, Equinix now discusses AI deployments above 200 kW per rack and future systems that could approach 1 MW. That is far beyond the roughly 5–10 kW rack densities around which a large part of the existing data center estate was built.
Cooling vendors are already designing around that gap. Schneider Electric's Motivair portfolio includes CDUs reaching 2.5 MW per unit, with coordinated systems designed to scale beyond 10 MW. Vertiv is qualifying multi-megawatt CDUs for NVIDIA AI-factory infrastructure. Airedale by Modine has introduced chillers above 3 MW specifically for large AI facilities.
Higher chip power is forcing changes from the server rack through pumping, water loops, controls, chillers and heat rejection. For the densest AI clusters today, thermal infrastructure has moved onto the critical path of the project.
Is liquid cooling really taking over data centers now?
Liquid cooling is taking over the densest AI racks, but most data centers are still nowhere close to becoming fully liquid cooled.
Uptime Institute's latest global work is a useful reality check. Typical rack densities are still moving upward gradually, even though more operators now report peak racks above 30 kW. Uptime has also found that direct liquid cooling remains concentrated in the applications where air cooling is becoming impractical.
That leaves two markets running in parallel. Frontier GPU clusters are moving rapidly toward direct liquid cooling, while most enterprise servers, storage, networking equipment and older racks still run comfortably with air.
The latest products increasingly assume that both will coexist. Schneider recently launched a CDU designed specifically to work with fan-wall air cooling so operators can change the balance between liquid and air without redesigning the entire data hall. Munters' roughly SEK 2 billion US AI cooling order combines high-capacity CDUs with over-rack computer-room air handlers. Digital Realty and Vertiv are also designing high-density environments around mixed cooling.
What does it actually mean to capture AI cooling demand?
A cooling company captures AI demand when higher GPU densities increase how much customers spend with it and that relationship survives beyond the first equipment order.
Rapid unit growth alone does not necessarily create a great business. A cold-plate supplier can benefit enormously during a new GPU generation, yet still face redesign risk whenever server architectures change. A company supplying CDUs, chillers, controls, commissioning and maintenance can earn money at several stages of the same deployment.
Recent acquisitions show where large industrial companies think the valuable territory sits. Eaton paid $9.5 billion for Boyd Thermal, which had forecast roughly $1.5 billion of liquid-cooling sales for 2026. Schneider bought control of Motivair. Trane acquired LiquidStack. Vertiv has added cold-plate engineering, heat-rejection technology and fluid-management services through several transactions.
For this article, the strongest business model means more than having the fastest-growing technology. We are looking for companies that can capture a large amount of spending per megawatt, keep reasonable pricing power and continue selling into the installed base after the AI servers go live.
If you want more recent data on this point, please see our latest data center cooling market report.

Big announcements don't always turn into real results. Our data center cooling market report shows where things actually get stuck.
Will direct-to-chip liquid cooling become the default for AI servers?
Direct-to-chip liquid cooling currently has the clearest path to becoming the standard cooling architecture for very dense AI racks.
The attraction is practical. Cold plates take heat directly from GPUs and CPUs while the rest of the server or rack can still use air where needed. Operators can therefore handle far more heat without putting the entire machine into dielectric fluid or completely changing normal server servicing.
The hardware ecosystem is moving the same way. NVIDIA's GB200 and GB300 rack-scale systems are designed around liquid cooling. Schneider, Vertiv, Eaton through Boyd, Trane through LiquidStack, Munters and several specialists are all building direct-to-chip infrastructure around the same demand.
It also fits the retrofit market better than more radical architectures. Operators can add CDUs, manifolds and liquid loops to selected rows while leaving lower-density equipment alone.
Direct-to-chip looks strongest where chip heat is high enough to justify the added plumbing and operational complexity. That category is growing quickly because of AI accelerators, but it still represents only part of the broader data center installed base.
| Cooling approach | Density it can handle | Changes to existing servers | Retrofit fit | Commercial position today |
|---|---|---|---|---|
| Conventional air cooling | Low to medium | Minimal | Excellent | Still dominant outside dense AI |
| Rear-door heat exchangers | Medium | Minimal | Very good | Useful transition technology |
| Direct-to-chip liquid cooling | High | Moderate | Good | Strongest AI growth market |
| Liquid-to-air CDU systems | High | Moderate | Very good | Strong where facility water is limited |
| Liquid-to-liquid CDU systems | Very high | Moderate | Good | Core large AI-cluster architecture |
| Single-phase immersion | Very high | Major | Weak | Specialized |
| Two-phase immersion | Very high | Major | Weak | Technically strong, adoption still limited |
| Hybrid air plus direct liquid | High | Moderate | Excellent | Likely broadest deployment model |
Will immersion cooling beat direct-to-chip cooling for AI?
Immersion cooling should win some extreme-density applications, but direct-to-chip looks much more likely to capture the larger AI cooling market.
Immersion has genuine technical advantages. Putting computing hardware directly into dielectric fluid can remove large amounts of heat in a compact space. The harder part is getting customers to change server formats, maintenance procedures, component handling and sometimes warranty arrangements.
Direct-to-chip asks customers to add a liquid loop around familiar servers. Immersion changes much more of the operating model.
Commercial behavior reflects that difference. LiquidStack, one of the best-known immersion companies, expanded into direct-to-chip systems before being acquired by Trane. Trane now markets both technologies inside a much broader thermal portfolio. Large data center operators also tend to present immersion as one available architecture while direct-to-chip receives the heavier emphasis for mainstream high-density deployments.
Uptime Institute's research still points to operational complexity as one of the main things slowing direct liquid cooling outside the highest-density applications. Immersion adds another layer of change on top of that.
If you want more recent data on this point, please see our latest data center cooling market report.

Many players in this market still lose money on every sale. See who's closest to profit in our data center cooling market report.
Are coolant distribution units the cleanest way to bet on AI cooling?
CDUs are probably the clearest equipment play on the move toward liquid-cooled AI, although competition should get much tougher as the category matures.
A coolant distribution unit sits between the facility cooling system and the liquid loop serving the servers. It controls temperature, pressure and flow while keeping the sensitive IT-side loop separate from the building's water system. Once a data center shifts a large amount of heat into liquid, CDUs become difficult to avoid.
Product capacities show how quickly the category is moving. Schneider's Motivair line now reaches 2.5 MW per CDU and can coordinate systems above 10 MW. Vertiv has a 2.3 MW CDU qualified for NVIDIA's DSX infrastructure program. Munters' roughly SEK 2 billion US order includes custom high-capacity CDUs for a large AI build-out.
There is a fairly direct relationship between liquid-cooled megawatts and the amount of distribution capacity required. That gives CDU vendors strong exposure to AI infrastructure spending.
The catch is already visible: almost every serious cooling platform wants to sell them. Schneider, Vertiv, Munters, Airedale, LiquidStack and smaller specialists are competing in the same category. NVIDIA qualification programs and industry standards should also make it easier over time to compare systems from different suppliers.
Could chillers make more money from AI than cold plates and CDUs?
Yes. Chillers and heat-rejection systems could capture more absolute AI cooling spending than some of the liquid-cooling products getting far more attention.
Every watt of GPU heat ultimately has to go somewhere. Cold plates move heat away from the processors and CDUs transfer it between loops, but large facilities still need major equipment outside the server room to reject that heat.
Recent orders are already much larger than what we usually see in specialist rack-level cooling. Modine signed a long-term agreement giving one strategic customer access to more than $4 billion of Airedale cooling products over 2027–2029. The customer paid $165 million upfront to support the capacity needed to fulfill that commitment.
Munters has also reported billion-krona data center cooling orders, including large chiller contracts, while its Data Center Technologies backlog reached SEK 15.2 billion after more than doubling year over year in its first-quarter reporting. Vertiv is currently doubling chiller production capacity at its Tognana site in Italy.
Those numbers make the economics easier to see. AI is creating a rapidly growing market for CDUs and cold plates, but it is also pushing huge amounts of spending into industrial-scale chilled-water and heat-rejection equipment.
If you want more recent data on this point, please see our latest data center cooling market report.

Bigger than you think, or smaller? Our data center cooling market report puts real numbers on it.
Why are hybrid air-and-liquid cooling systems winning now?
Hybrid cooling is becoming the practical default for many AI data centers because most facilities do not need liquid cooling on every rack.
A modern AI hall can contain liquid-cooled GPU systems beside networking, storage and less dense compute that still works perfectly well with air. Existing data centers make this mixture even more obvious because operators rarely replace thousands of functioning air-cooled racks simply to install a few rows of new accelerators.
Recent product development is lining up around that reality. Schneider's newest WCDU is designed to work directly with fan-wall air systems and lets operators change the balance between air and liquid cooling later. Munters' large AI order pairs CDUs with over-rack air handlers. Vertiv offers modular systems combining direct-to-chip liquid cooling with air cooling.
Uptime Institute's latest data adds another reason to be cautious about an all-liquid future. Typical rack densities across the industry are still far below the extreme numbers associated with the newest GPU systems. Its current view is that liquid cooling should remain concentrated in high-density applications over the next several years.
Is retrofitting old data centers a real AI cooling business?
Yes. Retrofitting existing data centers should create a large market for cooling engineering and integration because most older facilities were never built for today's AI racks.
The gap can be enormous. A facility designed around 5–10 kW racks can require substantial changes before it can host racks drawing many tens or hundreds of kilowatts. The work can involve piping, pumps, CDUs, electrical distribution, chillers, heat exchangers, controls and new operating procedures.
That makes retrofit cooling very different from simply shipping equipment.
Vertiv's work installing NVIDIA DGX GB300 infrastructure at the US Naval Postgraduate School provides a useful example. The project combined power protection, racks, liquid cooling, fluid management, installation, testing and commissioning inside an existing environment. The value came from making the whole deployment work together.
Colocation operators are solving the same problem on behalf of customers. Equinix has been adding liquid-cooling capability across its footprint so companies can deploy dense AI hardware without rebuilding their own facilities first.
A standardized CDU can eventually face intense price competition; an engineering team that knows how to put new liquid infrastructure safely inside an awkward 15-year-old facility is harder to replace.

Rules can make or break this market, and companies know it. Our data center cooling market report covers who's shaping them.
Are chip-to-chiller cooling platforms the strongest AI cooling business model?
Yes. Companies that can cover most of the path from the server to heat rejection currently have the strongest overall position in AI cooling.
Look at where the large industrial buyers have been spending. Schneider combined its power and cooling portfolio with Motivair's CDUs and liquid infrastructure. Eaton completed the $9.5 billion acquisition of Boyd Thermal, adding cold plates and other liquid-cooling technology to a huge data center power business. Trane acquired LiquidStack to connect direct-to-chip and immersion cooling with chillers, heat rejection and controls.
Vertiv has followed a similar route through multiple smaller transactions. It added Strategic Thermal Labs for cold-plate and server-side engineering, ThermoKey for heat rejection and more recently agreed to acquire King Environmental Services for fluid management and commissioning in Europe, the Middle East and Africa.
The pattern has become even clearer lately. Trane's newest 250 MW AI-factory reference designs combine its own thermal equipment with LiquidStack and Stellar Energy technologies. Schneider's newest hybrid CDU links liquid distribution directly with fan-wall air cooling.
Software fits naturally into the same model. Schneider connects liquid cooling into EcoStruxure, while Vertiv is developing monitoring, digital-twin and infrastructure-management tools around its hardware. Controls become more valuable as pumps, CDUs, chillers and variable AI loads need to react together.
| Business model | What it sells | Main advantage in AI | Main weakness | Current position |
|---|---|---|---|---|
| Cold-plate specialist | Cold plates and manifolds | Very close to GPU demand | Server-design and qualification risk | Fast-growing |
| CDU specialist | Distribution, pumping and controls | Scales with liquid-cooled MW | More vendors entering | Very strong near term |
| Chiller specialist | Chillers and heat rejection | Huge facility-level spending | Less unique to AI | Underappreciated winner |
| Integrated thermal platform | Rack-to-facility cooling | Captures several spending layers | Harder to execute | Strongest overall model |
| Retrofit integrator | Design, piping and commissioning | Legacy facilities are difficult | Labor intensive | Attractive fragmented market |
| Fluid-management provider | Flushing, filtration, testing | Recurring installed-base demand | Smaller initial contract size | Growing quickly |
| AI-ready colocation | High-density capacity | Sells cooling capability as a service | Extremely capital intensive | Strong enterprise model |
| Immersion specialist | Immersion tanks and fluids | Handles extreme density | Bigger operational change | Valuable niche |
If you want more recent data on this point, please see our latest data center cooling market report.
Can specialist liquid-cooling companies still beat Schneider, Vertiv or Trane as cooling hardware standardizes?
Specialist liquid-cooling companies can still build valuable businesses, but they need stronger technology or customer lock-in as CDUs and cold plates become easier to compare.
Specialists often move faster technologically. Cold plates, dielectric fluids, immersion systems and new distribution architectures can come from focused engineering teams long before they become priorities for large industrial companies.
The problem appears when a hyperscaler wants thousands of units across several continents. Qualification, manufacturing capacity, spare parts, service engineers and integration with the rest of the thermal plant suddenly matter almost as much as the component itself.
The acquisition market shows how this usually plays out. Schneider bought Motivair. Eaton bought Boyd Thermal. Trane bought LiquidStack. Vertiv bought Strategic Thermal Labs rather than relying entirely on internal development.
Boyd shows how valuable a specialist can become before being absorbed. Eaton's $9.5 billion purchase price represented 22.5 times Boyd Thermal's estimated 2026 adjusted EBITDA. Boyd was forecasting $1.7 billion of sales for the year, including roughly $1.5 billion from liquid cooling.
At the same time, standardization is starting to reduce some of the protection around individual products. Programs such as NVIDIA DSX Ready give customers clearer qualification requirements and make it easier to compare suppliers. Interoperability should help liquid cooling spread faster, but it also gives purchasing departments more bargaining power once several vendors can perform the same job.
Cold plates could eventually face similar pressure if interfaces and thermal requirements become more standardized across server generations.
The specialist businesses with the best chance are the ones that become difficult to replace before the category commoditizes: companies with deep server-OEM relationships, qualified designs, genuinely better thermal performance or enough manufacturing scale to serve very large deployments.

Demand is one thing, delivering is another. See the gap in our data center cooling market report.
Are cooling maintenance and fluid services the best recurring-revenue business?
Cooling maintenance, commissioning and fluid management may become the most attractive recurring-revenue layer created by AI liquid cooling.
Liquid systems introduce pumps, filters, valves, hoses, seals, heat exchangers and coolant chemistry close to servers worth millions of dollars. Contamination, corrosion, trapped air, poor flow balancing or bad fluid quality can cause performance problems that operators have little appetite to experiment with.
The market is already moving beyond installation. Vertiv acquired PurgeRite to expand fluid-management capabilities in North America and recently agreed to acquire King Environmental Services, which provides flushing, filtration, water treatment, commissioning, load testing and related services in Europe.
The timing is important. The first large wave of direct-liquid infrastructure is now creating an installed base that will need attention for years. Every additional megawatt deployed adds future maintenance rather than simply another one-time hardware sale.
Munters and other large cooling suppliers are also attaching startup and commissioning work to equipment contracts. Retrofit projects naturally create even more service work because older facilities require custom testing and integration.
Margins will vary, and this market is smaller in upfront dollars than multi-megawatt chiller orders. Its quality is potentially better, though. Once a provider is trusted to maintain the fluid system surrounding very expensive GPUs, changing contractors to save a small amount of money becomes less appealing.
Will water shortages change which AI cooling companies win?
Yes. Water availability is becoming important enough to influence cooling design, especially for giant AI campuses in places where water use already creates permitting or community problems.
The opportunity is more complicated than a race to claim “waterless” cooling. Operators still have to manage electricity use, capital costs, reliability and outside-air conditions.
Large suppliers are now designing around those trade-offs. Trane recently introduced two 250 MW AI-factory reference designs built around zero-water cooling. The designs combine technologies from Trane, LiquidStack and Stellar Energy and are meant for NVIDIA DSX-based facilities. Johnson Controls has also developed large zero-water reference architectures for AI data centers.
Dry cooling and air-cooled chillers can cut water use dramatically, although they may carry an energy or equipment penalty under certain weather conditions. Direct-to-chip systems can also use closed loops while changing how heat is ultimately rejected outside the building.
If access to water becomes one of the reasons a 500 MW campus cannot be permitted, a cooling architecture that avoids that constraint can be worth far more than the difference in equipment cost.

Still early or already mainstream? Our data center cooling market report answers that with real numbers.
Is manufacturing capacity becoming part of the AI cooling business?
Yes. For large AI projects today, being able to guarantee thousands of cooling units on time is becoming a product in its own right.
Modine provides the clearest example. One strategic customer agreed to secure more than $4 billion of future Airedale cooling capacity for deliveries over 2027–2029 and paid $165 million upfront to help Modine build the capacity required.
That arrangement says something unusual about the market. The customer was willing to finance part of its supplier's expansion to reduce the risk that cooling equipment becomes a bottleneck later.
Vertiv is making the same constraint visible from the supplier side. The company is doubling chiller production capacity at its Tognana campus and has opened additional manufacturing capacity in Johor, Malaysia, for power, cooling and integrated infrastructure serving Asian AI demand.
Munters' growing backlog adds another piece. Its data center business has collected several very large multi-year orders, including the roughly SEK 2 billion AI cooling project combining CDUs and air handlers.
These orders are no longer just about who has the best thermal specification. Customers also need confidence that a supplier can build, test, ship and service equipment across a multi-hundred-megawatt rollout.
Which AI data center cooling business models have the best economics?
Integrated thermal platforms look strongest overall, while fluid services offer the cleanest recurring revenue and CDUs provide some of the highest direct exposure to near-term liquid-cooling growth.
The differences come from how each model gets paid. Cold-plate and CDU suppliers benefit immediately when more GPU racks move to liquid. Chiller vendors capture large facility-level orders. Integrated platforms can sell several of those products into the same project. Service companies collect smaller amounts repeatedly after installation.
Immersion has attractive technical economics in specific environments but still carries more adoption risk. Conventional air cooling remains a large business, particularly inside hybrid facilities, although its revenue is less directly tied to the most extreme AI density growth.
| Business model | Exposure to AI demand | Recurring revenue | Pricing protection | Capital needed | Our assessment |
|---|---|---|---|---|---|
| Integrated thermal platform | Very high | High | High | High | Best overall model |
| Direct-to-chip components | Very high | Medium | High for qualified designs | Medium | Excellent growth |
| CDU platforms | Very high | Medium | Medium | Medium | Major near-term winner |
| Chillers and heat rejection | Very high | High | Medium-high | High | Underestimated winner |
| Retrofit engineering | High | High | High | Low-medium | Very attractive fragmented market |
| Fluid management and service | High | Very high | High | Low-medium | Best recurring-revenue layer |
| AI-ready colocation | Very high | Very high | High | Very high | Strong but infrastructure-heavy |
| Immersion cooling | Medium | Medium | Potentially high | Medium | Valuable specialist market |
| Air-only cooling | Medium | Medium | Medium | Medium | Large market, weaker direct AI leverage |
If you want more recent data on this point, please see our latest data center cooling market report.

Investors don't value every company the same way. Our data center cooling market report explains who gets the premium and why.
Which data center cooling business models will capture the most AI demand?
Integrated chip-to-chiller platforms should capture the largest and most durable share of AI cooling demand, with CDUs, large chillers and lifecycle services emerging as the strongest individual businesses underneath them.
The evidence has become unusually consistent. Eaton paid $9.5 billion for Boyd Thermal to connect power infrastructure with liquid cooling. Schneider added Motivair and is now linking CDUs, air cooling and controls. Trane bought LiquidStack and is already using it inside 250 MW AI-factory thermal designs. Vertiv has expanded in both directions, adding server-side engineering, heat rejection and fluid-management services.
Direct-to-chip should capture the fastest structural growth inside the rack. CDUs sit in an excellent position immediately behind it. Large chillers and heat-rejection systems may collect even more dollars at the facility level, especially as AI campuses move from tens of megawatts toward hundreds.
Hybrid cooling should also capture more demand than an all-liquid thesis suggests. Uptime Institute's latest work still shows a much less dense broader data center market, while Schneider's newest hardware and Munters' recent AI orders explicitly combine liquid and air cooling.
Services become increasingly attractive as that installed base expands. Fluid management, commissioning, maintenance and monitoring generate revenue long after the first rack has been delivered.
Manufacturing scale provides the final advantage. Modine's $4 billion capacity agreement and the factory expansions underway at Vertiv show that AI developers increasingly value guaranteed delivery alongside cooling performance.
The conclusion is clear today: selling a clever cooling component can build a fast-growing company, but controlling more of the path from the GPU to the outside environment creates the stronger business.
Our methodology
This analysis tests which data center cooling business models are most likely to capture AI demand as accelerator power, rack density and AI-campus scale increase. We compare the main cooling architectures and business models across direct exposure to AI deployment, spending captured per megawatt, retrofit potential, recurring revenue, manufacturing scale and the ability to participate in several parts of the same thermal system.
We separated technical capability from commercial adoption. A cooling architecture can handle extremely high heat loads without becoming the largest market, so direct-to-chip, immersion, hybrid air-and-liquid systems and facility-level cooling were assessed through practical deployment factors such as compatibility with existing infrastructure, operational change, qualification requirements, retrofitability and manufacturing availability.
We gave more weight to evidence of what customers and suppliers are actually doing than to broad market forecasts. That included disclosed orders and backlogs, NVIDIA-qualified cooling hardware, reference architectures, real deployments, acquisitions, manufacturing-capacity investments and operator survey data.
The business-model comparison also distinguishes between initial equipment revenue and the value of the installed base. Cold plates and CDUs benefit directly from new liquid-cooled racks, chillers and heat rejection capture facility-level spending, while commissioning, fluid management, maintenance and controls can continue generating revenue after the original deployment.
Individual announcements were treated as evidence rather than conclusions on their own. The final judgment comes from patterns that appear across several suppliers and customers at once, particularly the move toward direct-to-chip liquid cooling, hybrid facilities, larger CDU and chiller systems, integrated thermal platforms and lifecycle fluid services.
Key sources used for this analysis include NVIDIA on the GB200 NVL72 architecture, NVIDIA on the GB300 NVL72 architecture, Uptime Institute's 2026 Cooling Systems Survey, Uptime Institute on direct-liquid-cooling adoption, Schneider Electric on its 2.5 MW Motivair CDU platform, Eaton on its $9.5 billion Boyd Thermal acquisition, Trane Technologies on the LiquidStack acquisition, Vertiv on its NVIDIA DSX Ready 2.3 MW CDU, Modine on its $4 billion Airedale capacity agreement, and Munters on its SEK 2 billion modular AI cooling order.
We also used Vertiv's cooling-capacity expansion, Vertiv's PurgeRite fluid-management acquisition, Trane's 250 MW zero-water AI-factory reference designs, Johnson Controls' air-cooled AI-factory reference architecture, and Equinix on expanding direct-to-chip liquid-cooling capability across its footprint.

Market size is where every investment case starts. Get the full picture in our data center cooling market report.
Written by the New Market Pitch teamWe track new markets so founders and investors can move faster. About us